Brand-neutral size chart
Which size portable power station fits your outage?
This 12-model chart starts with the loads and runtime you need, then compares stored energy, usable-energy evidence, continuous output, and startup capability across Anker, EcoFlow, Jackery, and BLUETTI.
Use four numbers, not one capacity badge
Rated watt-hours describe stored energy before conversion losses. Usable AC watt-hours are the energy basis used for runtime. Continuous watts screen the combined running load. Startup or surge capability screens the brief demand created when motors and compressors start.
estimated hours = usable AC Wh × (1 − reserve) ÷ average selected-load wattsThe calculator applies a 10% reserve by default. Solar recharge is kept outside the first runtime number so an uncertain weather assumption cannot hide an undersized battery.
Measured and planning rows are intentionally different
Five models use shared-method measured AC energy from the current capacity comparison. The seven broader-catalog models use 85% of official rated capacity as a clearly labeled planning basis until comparable measurements are available. A planning row is not a test result.
Review the measured-capacity evidence →Compact: under 1 kWh
Shorter essential-load plans where portability matters and the screened load stays within the lower output limits.
| Model | Rated storage | Usable-energy basis | Continuous output | Startup screen | Official page |
|---|---|---|---|---|---|
| Jackery Explorer 600 v2 | 640Wh | 544Wh · 85% planning | 500W | 1,000W surge | View model ↗ |
| Anker SOLIX C800 Plus | 768Wh | 653Wh · 85% planning | 1,200W | 1,200W conservative continuous limit | View model ↗ |
| EcoFlow RIVER 3 Max Plus | 858Wh | 729Wh · 85% planning | 600W | 600W conservative continuous limit | View model ↗ |
Core outage class: about 1 kWh
Refrigeration, communications, lights, charging, and other selected plug-in essentials when the actual load passes both output checks.
| Model | Rated storage | Usable-energy basis | Continuous output | Startup screen | Official page |
|---|---|---|---|---|---|
| Anker SOLIX C1000 Gen 2 | 1,024Wh | 890Wh · shared-method measured | 2,000W | 3,000W peak | View model ↗ |
| EcoFlow DELTA 3 | 1,024Wh | 870Wh · shared-method measured | 1,800W | 3,600W surge | View model ↗ |
| Jackery Explorer 1000 v2 | 1,070Wh | 910Wh · shared-method measured | 1,500W | 3,000W surge | View model ↗ |
| BLUETTI Elite 100 V2 | 1,024Wh | 890Wh · shared-method measured | 1,800W | 1,800W conservative verified limit | View model ↗ |
Extended portable: 2–3 kWh
Longer essential-load plans or larger supported plug-in loads, with more weight and cost than the 1 kWh class.
| Model | Rated storage | Usable-energy basis | Continuous output | Startup screen | Official page |
|---|---|---|---|---|---|
| Jackery Explorer 2000 v2 | 2,042Wh | 1,710Wh · shared-method measured | 2,200W | 4,400W instantaneous | View model ↗ |
| BLUETTI Elite 200 V2 | 2,074Wh | 1,763Wh · 85% planning | 2,600W | 2,600W conservative continuous limit | View model ↗ |
| Anker SOLIX F2600 | 2,560Wh | 2,176Wh · 85% planning | 2,400W | 2,800W surge | View model ↗ |
| BLUETTI Apex 300 | 2,765Wh | 2,350Wh · 85% planning | 3,840W | 3,840W conservative continuous limit | View model ↗ |
Large portable ecosystem: 4 kWh
High stored energy and output for demanding portable or manufacturer-supported modular configurations; fixed-circuit work still requires professional review.
| Model | Rated storage | Usable-energy basis | Continuous output | Startup screen | Official page |
|---|---|---|---|---|---|
| EcoFlow DELTA Pro 3 | 4,096Wh | 3,482Wh · 85% planning | 4,000W | 4,000W conservative continuous limit | View model ↗ |
A simple selection sequence
- 1Select the must-run items.
Start with the refrigerator, communications, lighting, charging, medical equipment, pumps, or other loads that matter during your outage.
- 2Correct the assumptions.
Verify running watts, startup demand, and hours per day from labels, manuals, or suitable measurements.
- 3Screen power before runtime.
Remove any model that cannot support the simultaneous running demand or conservative startup demand.
- 4Compare battery-only hours.
Use the same reserve and load schedule for every qualifying model; add solar as a separate scenario.
- 5Rehearse before relying on it.
Test the actual station, cables, settings, and appliance combination, then replace planning assumptions with observed results.
Commercial and safety boundary
This chart is not commission-ranked. All 12 product buttons lead to official manufacturer pages and are untracked; no affiliate relationship or commission is active. Prices are omitted because they change and do not alter load compatibility.
The chart covers portable plug-and-play planning. It does not approve fixed wiring, transfer equipment, 240-volt connections, panel integration, or medical-backup adequacy. Verify current manuals and use appropriately licensed professionals for fixed systems.